We realise the plan to its measurement according to the effective legislation for companies of small spread until multinationals:
Evaluation of risk
Average of protection
General plan of emergencia
Implantation
2. Sectorisation and Compartmentation of the Buildings:
The confinement of the fire
Fire resistance
R.D. 312/2005, Classification of Products of Construction and the Constructive Elements based on its Properties of Reaction and Resistance In front of the Fire.
Influence of the compartmentation in the protection of the buildings
Requirements of fire resistance based on the typology of the building and the activity
Movable doors, floodgates and partitions fire-guards.
Conduits of air conditioning and ventilation
Protection of facades and covers
The compartmentation in wagon, railway and suburban tunnels
3. Reaction to the Fire of the Materials:
R.D 312/2005. Classification of Products of Construction of the Constructive Elements based on its Properties of Reaction and Resistance In front of the Fire.
Reaction to the fire of the materials that compose the finished ones and superficial coatings of grounds, walls and ceilings of the buildings.
Influence in the beginning and development of the fire
4. Control systems of Temperature and Evacuation of Smoke:
Basic concepts.
Typology of buildings. Buildings of a plant, stand with vestibule, stand with stairs and cellars
Control of smoke and temperature in building of a plant
Control of smoke and temperature in buildings stands with vestibule
Specific materials of the S.C.H.T
Interaction of the S.C.H.T with other facilities of P.C.I
Pressurization and ventilation of the routes of evacuation according to pr EN12101/6
Suburban ventilation in tunnels of highways, railway and
5. Facilities of Fire extinguishing :
Foundations of the extinction
Mechanisms of extinction and quench agents
Manual extinguishers. Types and requirements
Mechanics of flowed for PCI facilities
Determine the proportions calculation and of hydraulic facilities
Equipped Fire mouths. Product requirements and criteria of design
Networks of Hydrants. Design and implantation
Automatic sprayers. Typologies and criteria of design
Automatic sprayers. Typologies and criteria of design
Nebulizada water. Design and Approvals
Systems by foam. Applications and criteria of design
Groups of pressure and water reserve.
Networks of Water supply for PCI
Systems of extinction by gas: CO2, HFC and IG. Criteria of design and applications according to the selected agent
Other quench agents
6. Facilities of Fire Detection:
Components of the Systems of detection and fire alarm
Criteria of design of facilities
Typologies and selection of systems of automatic detection
Systems ASD
7. Facilities of Emergencia:
Emergency lighting
Signaling
Secondary feed or of emergencia
Elevator of emergencia
8. Special facilities:
Explosive atmosphere facilities
Facilities in singular typologies
Antit Fires it stops | Buildings | The Commercial premises | Industrial ships | Ports Airports